Degree of protection of light fixtures against the penetration of solids and liquids.
IEC 529 - EN 60529 Standard.
(First digit – Solids / Second digit – Liquids)
IP55
5. Protected against dust penetration.
5. Protected against jets of water.
IP65
6. Hermetically protected against dust.
5. Protected against jets of water.
IP66
6. Hermetically protected against dust.
6. Protected against sea swells and similar.
Degree of protection against mechanical impacts provided by the enclosure.
In accordance with EN 50102.
IK08 (0.5 J), IK09 (1 J), IK10 (2 J).
CLASS I.
Functional insulation in all its parts and ground connection.
CLASS II.
Double reinforced insulation to avoid voltage in exposed metal parts.
Product certificates
All our products comply with applicable European Directives and Standards, authorizing free circulation within the European Economic Area (EEA). We also comply with the Electromagnetic Compatibility (EMC) Directive and the Low Voltage Directive. We certify with ENAC-accredited external laboratories.
Analysed Impact Categories
The life-cycle analyses have been performed using the guidelines ISO 14040 (Life cycle analysis – Principles and framework) and ISO 14044 (Environmental management – Life cycle assessment – Requirements and guidelines).
Acidification
Indicator of potential acidification of soils and water (increase in pH). Associated with the death of plantlife, low crop yields, soil infertility, contamination of water-based ecosystems, etc.
Method and unit
EF v3.1 | acidification | accumulated excess (AE) (mol H+-Eq)
Climate Change
Indicator of greenhouse gas emissions (GHG) which contribute to climate change in the atmosphere. Associated with the increase in temperatures and changes in climate patterns due to the greenhouse effect.
Method and unit
IPCC 2021 | climate change | global warming potential (GWP100) (kg CO2-Eq)
Ecotoxicity
Indicator that measures the toxic effects of chemical compounds in the ecosystem. Associated with the bioaccumulation of toxic compounds, the death of living organisms and the alteration or breakdown of ecosystems.
Method and unit
USEtox | ecotoxicity | total (CTU)
Depletion of Fossil Fuels
Indicator of the depletion of non-renewable fossil fuels. Associated with the concern that these limited energy resources will not be available in the future based on current consumption patterns.
Method and unit
CML v4.8 2016 | energy resources: non-renewable | abiotic depletion potential (ADP): fossil fuels (MJ)
Eutrophication
Indicator of the enrichment of the freshwater ecosystem with nutrients. Associated with the excessive growth of algae in bodies of water, a lack of oxygen and the death of aquatic organisms.
Method and unit
CML v4.8 2016 | eutrophication (kg PO4-Eq)
Land Use for Agriculture
Indicator of the use and transformation of land with agricultural potential for other purposes, such as forests, roads, industrial areas and mineral extraction, among others.
Method and unit
ReCiPe 2016 v1.03, midpoint (H) | land use | use of agricultural land (LOP) (m2 cultivo-Eq)
Depletion of Minerals and Metals
Indicator of depletion of metal and mineral resources. Associated with the concern that these extremely scarce, non-renewable resources will not be available in the future.
Method and unit
CML v4.8 2016 | material resources: metals/minerals | abiotic depletion potential (ADP): elements (last reserves) (kg Sb-Eq)
Water Use
Analysis of water use in transformation processes. Water use can stem from a wide range of sources, from its direct use in production processes to its indirect use in hydroelectric power.
Method and unit
ReCiPe 2016 v1.03, midpoint (H) | water consumption potential (WCP) (m3 H2O)
Innocence and Harmony for Urban Space
Resilient and durable, the Eden system combines powder-coated aluminum and inner containers that facilitate gardening. Configurable for different sizes and functions, it can include a bench in the linear planter, and a bench and railing integrated into the flower bed. A versatile offer that promotes citizens’ well-being.
Linear planter:
- Side panels made of extruded 6063-T5 aluminium and anodised aluminium end caps with powder-coated finish.
- Lower fastening base made of hot-dip galvanised grating S235JR steel.
- PP polypropylene tanks.
- A2 stainless steel hardware.
Flower bed:
- Anodised extruded aluminium 6063-T5 structure with powder-coated finish.
- Side panels made of anodised extruded aluminium 6063-T5 powder-coated finish.
- Variant with slatted bench made of tropical wood, 100% FSC certified.
- PP polypropylene tanks.
- A2 stainless steel hardware.
Green
The colours shown are purely indicative.
Other colours are available upon request.
Check finishes for marine environments.
Linear Planter
Flower Bed
- The linear planter does not require anchoring to the pavement and the flower bed must be anchored.
- The element is supplied disassembled and packaged.
- Installation and assembly instructions included.
- Volume of substrate per tank: 0.06 m3.
- Does not require maintenance.
- Clean using pH neutral, alcohol-free, nonabrasive cleaning products.
CE
Typology