Commercial network

Commercial network

Lighting classification

Degree of protection of light fixtures against the penetration of solids and liquids.
IEC 529 - EN 60529 Standard.

(First digit – Solids / Second digit – Liquids)

IP55
5. Protected against dust penetration.
5. Protected against jets of water.

IP65
6. Hermetically protected against dust.
5. Protected against jets of water.

IP66
6. Hermetically protected against dust.
6. Protected against sea swells and similar.

Degree of protection against mechanical impacts provided by the enclosure.
In accordance with EN 50102.
IK08 (0.5 J), IK09 (1 J), IK10 (2 J).

CLASS I.
Functional insulation in all its parts and ground connection.

CLASS II.
Double reinforced insulation to avoid voltage in exposed metal parts.

Product certificates

All our products comply with applicable European Directives and Standards, authorizing free circulation within the European Economic Area (EEA). We also comply with the Electromagnetic Compatibility (EMC) Directive and the Low Voltage Directive. We certify with ENAC-accredited external laboratories.

The certification guarantees the design, testing, evolution, manufacturing and assembling of approved products, in accordance with the applicable safety standards in the U.S. and Canada. Our light fixtures are classified according to the UL Standards for different environments.

We comply with the Restriction of Hazardous Substances (RoHS) Directive for electrical and electronic components. We also comply with the Waste Directive (RAEE/WEEE) for respectful waste management.

Classification of the tree presentation formats

We have classified the different tree presentation formats that you can find in our nursery from 1 (lowest grade) to 3 (highest grade). We think that the following parameters are key for the correct establishment of specimens in their final locations.

 

Grade Rooting Planting Circling Growth Residue Total
Bare roots 2 1 3 1 3 10
Root ball 2 2 3 2 3 12
Container 3 3 2 3 1 12
Air-Pot ® 3 3 3 3 3 15

Analysed Impact Categories

The life-cycle analyses have been performed using the guidelines ISO 14040 (Life cycle analysis – Principles and framework) and ISO 14044 (Environmental management – Life cycle assessment – Requirements and guidelines).

Acidification

Indicator of potential acidification of soils and water (increase in pH). Associated with the death of plantlife, low crop yields, soil infertility, contamination of water-based ecosystems, etc.

Method and unit

EF v3.1 | acidification | accumulated excess (AE) (mol H+-Eq)

Climate Change

Indicator of greenhouse gas emissions (GHG) which contribute to climate change in the atmosphere. Associated with the increase in temperatures and changes in climate patterns due to the greenhouse effect.

Method and unit

IPCC 2021 | climate change | global warming potential (GWP100) (kg CO2-Eq)

Ecotoxicity

Indicator that measures the toxic effects of chemical compounds in the ecosystem. Associated with the bioaccumulation of toxic compounds, the death of living organisms and the alteration or breakdown of ecosystems.

Method and unit

USEtox | ecotoxicity | total (CTU)

Depletion of Fossil Fuels

Indicator of the depletion of non-renewable fossil fuels. Associated with the concern that these limited energy resources will not be available in the future based on current consumption patterns.

Method and unit

CML v4.8 2016 | energy resources: non-renewable | abiotic depletion potential (ADP): fossil fuels (MJ)

Eutrophication

Indicator of the enrichment of the freshwater ecosystem with nutrients. Associated with the excessive growth of algae in bodies of water, a lack of oxygen and the death of aquatic organisms.

Method and unit

CML v4.8 2016 | eutrophication (kg PO4-Eq)

Land Use for Agriculture

Indicator of the use and transformation of land with agricultural potential for other purposes, such as forests, roads, industrial areas and mineral extraction, among others.

Method and unit

ReCiPe 2016 v1.03, midpoint (H) | land use | use of agricultural land (LOP) (m2 cultivo-Eq)

Depletion of Minerals and Metals

Indicator of depletion of metal and mineral resources. Associated with the concern that these extremely scarce, non-renewable resources will not be available in the future.

Method and unit

CML v4.8 2016 | material resources: metals/minerals | abiotic depletion potential (ADP): elements (last reserves) (kg Sb-Eq)

Water Use

Analysis of water use in transformation processes. Water use can stem from a wide range of sources, from its direct use in production processes to its indirect use in hydroelectric power.

Method and unit

ReCiPe 2016 v1.03, midpoint (H) | water consumption potential (WCP) (m3 H2O)

Latina
Latina
Latina
Latina
Latina

Prominence and functionality

It consists of two recognizable parts: a forked shaft and two tubes, where one acts as a support for up to 5 Arne floodlights, and the other acts as a brace that provides stability for the assembly. The Latina streetlight signifies urban space with functional prominence.

-
  • Anodised injected aluminium EN-AC-47100 floodlight with powder-coated finish.
  • Interior ABS-PC plastic reflector.
  • Tempered optical glass diffuser.
  • A2 stainless steel hardware and metal cable gland.
  • Corten steel shaft that is 7 m in height, with a rectangular section base and upper segment of forked section.
  • Rectangular tube section support for five floodlights made from hot-dip galvanized steel.
  • Round tube brace made from hot-dip galvanized steel. Stainless steel joints.

Floodlight

Light grey

Light grey

Pole

Corten

Corten

Support

Galvanized

Galvanized

The colours shown are purely indicative.
Other colours are available upon request.
Check finishes for marine environments.

System power (W)

High efficiency optical unit

  • 36 LEDs 5x56W

 

Operating current (mA)

  • 500

 

Colour temperature (K)

  • 3000 CRI min80

 

Service life

TM21 L90 (10k) > 100.000 h.

Streetlight

Streetlight

Architectural

Wide Flood

All our products support remote regulation, both individually and in groups, through the most standardised control systems, significantly reducing energy consumption and eliminating light pollution. We adapt our products to safeguard biodiversity and respect circadian rhythms, eliminating harmful wavelengths.

Our luminaires comply with the American IESNA LM80 and TM21 standards.

1-10V / 0-10V

Analog one-way regulation protocol that, through a signal between 1 or 0 and 10 V, allows remote linear control of the luminous flux between 10% or 0% and 100%. The standard programming is as follows: Vi ≥ 8V – 100%; Vi ≤ 1V – 10%.

DALI

Two-way digital communication protocol (Digital Addressable Lighting Interface) that allows grouping, regulating, and turning off the luminaire, using an 8-bit resolution with 254 regulation steps and receiving information about its status for maintenance.

Programmes

Automatic programming

Individual, self-managed programming in the product and bi-directional. It is configured prior to installation. It is useful in projects that require a single pattern throughout the product’s life. It incorporates automatic regulation steps with geolocation and real nighttime cycles.

Example: 100% from 21:00 to 22:00; 70% from 22:00 to 01:00; 50% from 01:00 to 05:00; 70% from 05:00 to 08:00.

Automatic control panel programming

Individual, self-managed programming in the control panel and one-way. It is configured prior to installation. It can coexist with other analog voltage reduction technologies, such as phase-cut. It is useful in projects that need different patterns throughout the year or the product’s life.

Example: Summer 100% from 21:00 to 22:00; 70% from 22:00 to 01:00; 50% from 01:00 to 05:00; Winter 100% from 16:00 to 22:00; 70% from 22:00 to 01:00; 50% from 01:00 to 08:00.

Command line programming

Group regulation, in the control panel and one-way. It requires the installation of an additional control electrical line besides the power line (2×2.5mm2). It is useful in projects that need simplified regulation.

Lighting Flow dimmer programming

Group regulation, in the control panel and one-way. It requires the installation of a stabilizer/voltage regulator in the control panel and product configuration to interpret the correlation between line voltage and power. It is useful in projects that need a simplified system with existing regulators.

Example: Vi ≥ 230V – 100%; Vi ≤ 185V – 60%

Constant Luminous Management (CLM)

Optional function parallel to the programming that maintains the project illumination levels constant throughout the installation’s life, increasing the luminaire’s power proportionally to the LED depreciation. Our standard programming is 0h 80%; 60,000h 100%.

Temperature control

Optional automatic protection to safeguard the integrity of the lighting components. It monitors the maximum temperature, activating a flow reduction to recover an acceptable value.

Surge protection

Protector against voltage spikes caused by thunderstorms. Sized for a maximum discharge current of 10kA.

Lighting classification
  • Column fixed in a reinforced concrete block on-site, with a groove for electrical connection, and anchor bolts, 24 cm below the pavement level.
  • The element is supplied disassembled, in four components: column, support, brace and floodlights.
  • Installation and assembly instructions, screws, template, and anchor bolts included.
  • Includes pressure compensation valve and 10kV surge protector (CE).
  • Clean using pH-neutral, alcohol-free, and non-abrasive cleaning products.
certificats_CE

CE

certificats_c_UL_us

UL

certificats_ROHS

RoHs

certificats_IP-66-2

IP66

certificats_IK-08-1

IK08

certificats_clase I

Clase I

More information

Streetlight: 895

*Approximate weight without packaging (kg)

Downloads

-
descarga completa esperando respuesta...
0%

Message sent

Message sent

We work for greener, more connected and better cities for people. We’re here for you.

Upload files Maximum size: 7MB

Accepted formats: PDF, Word, JPG

Loading...
Send