Degree of protection of light fixtures against the penetration of solids and liquids.
IEC 529 - EN 60529 Standard.
(First digit – Solids / Second digit – Liquids)
IP55
5. Protected against dust penetration.
5. Protected against jets of water.
IP65
6. Hermetically protected against dust.
5. Protected against jets of water.
IP66
6. Hermetically protected against dust.
6. Protected against sea swells and similar.
Degree of protection against mechanical impacts provided by the enclosure.
In accordance with EN 50102.
IK08 (0.5 J), IK09 (1 J), IK10 (2 J).
CLASS I.
Functional insulation in all its parts and ground connection.
CLASS II.
Double reinforced insulation to avoid voltage in exposed metal parts.
Product certificates
All our products comply with applicable European Directives and Standards, authorizing free circulation within the European Economic Area (EEA). We also comply with the Electromagnetic Compatibility (EMC) Directive and the Low Voltage Directive. We certify with ENAC-accredited external laboratories.
We comply with the accessibility standards established by the Americans with Disabilities Act (ADA). Our products are designed to ensure inclusion and usability for people with diverse abilities, promoting accessible and equitable environments.
Analysed Impact Categories
The life-cycle analyses have been performed using the guidelines ISO 14040 (Life cycle analysis – Principles and framework) and ISO 14044 (Environmental management – Life cycle assessment – Requirements and guidelines).
Acidification
Indicator of potential acidification of soils and water (increase in pH). Associated with the death of plantlife, low crop yields, soil infertility, contamination of water-based ecosystems, etc.
Method and unit
EF v3.1 | acidification | accumulated excess (AE) (mol H+-Eq)
Climate Change
Indicator of greenhouse gas emissions (GHG) which contribute to climate change in the atmosphere. Associated with the increase in temperatures and changes in climate patterns due to the greenhouse effect.
Method and unit
IPCC 2021 | climate change | global warming potential (GWP100) (kg CO2-Eq)
Ecotoxicity
Indicator that measures the toxic effects of chemical compounds in the ecosystem. Associated with the bioaccumulation of toxic compounds, the death of living organisms and the alteration or breakdown of ecosystems.
Method and unit
USEtox | ecotoxicity | total (CTU)
Depletion of Fossil Fuels
Indicator of the depletion of non-renewable fossil fuels. Associated with the concern that these limited energy resources will not be available in the future based on current consumption patterns.
Method and unit
CML v4.8 2016 | energy resources: non-renewable | abiotic depletion potential (ADP): fossil fuels (MJ)
Eutrophication
Indicator of the enrichment of the freshwater ecosystem with nutrients. Associated with the excessive growth of algae in bodies of water, a lack of oxygen and the death of aquatic organisms.
Method and unit
CML v4.8 2016 | eutrophication (kg PO4-Eq)
Land Use for Agriculture
Indicator of the use and transformation of land with agricultural potential for other purposes, such as forests, roads, industrial areas and mineral extraction, among others.
Method and unit
ReCiPe 2016 v1.03, midpoint (H) | land use | use of agricultural land (LOP) (m2 cultivo-Eq)
Depletion of Minerals and Metals
Indicator of depletion of metal and mineral resources. Associated with the concern that these extremely scarce, non-renewable resources will not be available in the future.
Method and unit
CML v4.8 2016 | material resources: metals/minerals | abiotic depletion potential (ADP): elements (last reserves) (kg Sb-Eq)
Water Use
Analysis of water use in transformation processes. Water use can stem from a wide range of sources, from its direct use in production processes to its indirect use in hydroelectric power.
Method and unit
ReCiPe 2016 v1.03, midpoint (H) | water consumption potential (WCP) (m3 H2O)
A fountain with sensors
Manufactured to withstand rusting throughout, the Caudal fountain is also available in a touchless version, composed of a proximity actuator that provides the option of activating the fountain without physical contact.
- Body made from AISI 316 sheet stainless steel, thermal coating finish with C3 anti-corrosive protection. Anti-splash water evacuation mesh and interior tray made from AISI 316 stainless steel, electropolished finish.
- Jet made from brass, matte chrome finish and Presto model button.
- Pressure regulator and timed flow control included (an anti-icing valve can be included).
Corten
Electropolished
The colours shown are purely indicative.
Other colours are available upon request.
Check finishes for marine environments.
Drinking fountain
Drinking fountain for pets
- The element is fixed, using four mechanical wall plugs, 10 cm below the pavement.
- For temperatures ≤ 0ºC, it is recommended to shut off the water flow and empty the circuit in order to avoid freezing and breakages.
- The element is supplied assembled and packaged.
- Installation and assembly instructions, screws, and wall plugs included.
- Does not require maintenance, except for regular cleaning of the interior and the button.
CE
ADA
Typology